Details
EPS-S02-A03-B03-D11-D11-D05-N
ECOTOWER FP2 3KW RECTIFIER BASE, -48V/2400A OUTPUT
INCLUDES: CABINET, QTY 10 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT.
- CABINET: 24" WIDE, 24" DEEP, 7' HIGH (84" HIGH), SEISMIC CABINET
- EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 40 RECTIFIER POSITIONS
- SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS)
THREE PHASE 208VAC (3W+PE) INPUT, 3 RECTIFIERS PER AC INPUT FEED, FRONT ACCESS
INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX.
- AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE.
- CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY
- AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5" CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4"-20) AND MOUNTING BRACKETS
BATTERY BULK OUTPUT PANEL, 2400A WITH SHUNT
PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD
QTY 8 - 3/8" ON 1" CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25" PER CONNECTION
LOAD BREAKER DISTRIBUTION, 800A, INCLUDING:
- QTY 48 ONE POLE BULLET BREAKER POSITIONS WITH 48 LOAD HOT LANDINGS. EACH LANDING REQUIRES A TWO-HOLE LUG WITH 1/4" HOLE ON 5/8" CENTER, MAX CABLE TONGUE WIDTH OF 5/8" PER CONNECTION
-LOAD FUSE DISTRIBUTION, 1200A, INCLUDING:
- QTY 6 TPL FUSE POSITIONS OR 12 GJ BREAKER POSITIONS WITH 12 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8" HOLE ON 1" CENTER, MAX CABLE TONGUE WIDTH OF 1.5" PER CONNECTION
NO INTERNAL RETURN BUS BAR
Additional Info
Short Description | EPS-S02-A03-B03-D11-D11-D05-N ECOTOWER FP2 3KW RECTIFIER BASE, -48V/2400A OUTPUT INCLUDES: CABINET, QTY 10 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 40 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) THREE PHASE 208VAC (3W+PE) INPUT, 3 RECTIFIERS PER AC INPUT FEED, FRONT ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2400A WITH SHUNT PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION LOAD BREAKER DISTRIBUTION, 800A, INCLUDING: - QTY 48 ONE POLE BULLET BREAKER POSITIONS WITH 48 LOAD HOT LANDINGS. EACH LANDING REQUIRES A TWO-HOLE LUG WITH 1/4 HOLE ON 5/8 CENTER, MAX CABLE TONGUE WIDTH OF 5/8 PER CONNECTION -LOAD FUSE DISTRIBUTION, 1200A, INCLUDING: - QTY 6 TPL FUSE POSITIONS OR 12 GJ BREAKER POSITIONS WITH 12 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION NO INTERNAL RETURN BUS BAR |
---|---|
SKU | 306186 |
Product PDF | N/A |
HECI | No |
Manufacturer | Eltek |
Product Type | N/A |
Special Price | No |