EPS-S02-A03-B03-4D11-N
ECOTOWER FP2 3KW RECTIFIER BASE, -48V/2400A OUTPUT
INCLUDES: CABINET, QTY 10 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT.
- CABINET: 24" WIDE, 24" DEEP, 7' HIGH (84" HIGH), SEISMIC CABINET
- EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 40 RECTIFIER POSITIONS
- SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS)
THREE PHASE 208VAC (3P+PE) INPUT, 3 RECTIFIERS PER AC INPUT FEED, FRONT ACCESS
INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX.
- AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE.
- CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY
- AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5" CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4"-20) AND MOUNTING BRACKETS
BATTERY BULK OUTPUT PANEL, 2400A
PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD
QTY 8 - 3/8" ON 1" CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25" PER CONNECTION
SEE SECTION 5 "RETURN BUS PANEL" FOR BATTERY RETURN CONNECTION
TOTAL QTY 4 LOAD BREAKER DISTRIBUTIONS. EACH LOAD DISTRIBUTION, 800A, INCLUDING:
- QTY 24 ONE POLE BULLET BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS. EACH LANDING REQUIRES A TWO-HOLE LUG WITH 1/4" HOLE ON 5/8" CENTER, MAX CABLE TONGUE WIDTH OF 5/8" PER CONNECTION
NO INTERNAL LOAD RETURN BUS BAR INCLUDES:
- BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8"-16 NUTS ON 1" CENTER
Additional Info
Short Description | EPS-S02-A03-B03-4D11-N ECOTOWER FP2 3KW RECTIFIER BASE, -48V/2400A OUTPUT INCLUDES: CABINET, QTY 10 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 40 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) THREE PHASE 208VAC (3P+PE) INPUT, 3 RECTIFIERS PER AC INPUT FEED, FRONT ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2400A PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION SEE SECTION 5 RETURN BUS PANEL FOR BATTERY RETURN CONNECTION TOTAL QTY 4 LOAD BREAKER DISTRIBUTIONS. EACH LOAD DISTRIBUTION, 800A, INCLUDING: - QTY 24 ONE POLE BULLET BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS. EACH LANDING REQUIRES A TWO-HOLE LUG WITH 1/4 HOLE ON 5/8 CENTER, MAX CABLE TONGUE WIDTH OF 5/8 PER CONNECTION NO INTERNAL LOAD RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER |
---|---|
SKU | 317185 |
Product PDF | N/A |
HECI | No |
Manufacturer | Eltek |
Product Type | N/A |
Special Price | No |