Shop Now
-
TEMPERATURE PROBE, 470K NTC, NO LUG
TEMPERATURE PROBE, 470K NTC, NO LUG, 10FT Learn More -
RECTIFIER, 1120W, 53.5V, 20A, FAN C
RECTIFIER, 1120W, 53.5V, 20A, FAN C Learn More -
EPS-S13-A05-B04-D11-D11-D11-N ECOTO
EPS-S13-A05-B04-D11-D11-D11-N ECOTOWER 480VAC POWERPACK RECTIFIER BASE, -48V/2292A OUTPUT INCLUDES: CABINET, QTY 10 POWERPACK RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 1 RECTIFIER POSITIONS, TOTAL 10 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) THREE PHASE 480VAC (3W+PE) INPUT, 1 RECTIFIER PER AC INPUT FEED, FRONT ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2000A WITH LVBD AND SHUNT PANEL IS EQUIPPED WITH: LOW VOLTAGE BATTERY DISCONNECT AND 50mV/3000A SHUNT QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION LOAD BREAKER DISTRIBUTION, 800A, INCLUDING: - QTY 24 ONE POLE BULLET BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS. EACH LANDING REQUIRES A TWO-HOLE LUG WITH 1/4 HOLE ON 5/8 CENTER, MAX CABLE TONGUE WIDTH OF 5/8 PER CONNECTION LOAD BREAKER DISTRIBUTION, 800A, INCLUDING: - QTY 24 ONE POLE BULLET BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS. EACH LANDING REQUIRES A TWO-HOLE LUG WITH 1/4 HOLE ON 5/8 CENTER, MAX CABLE TONGUE WIDTH OF 5/8 PER CONNECTION LOAD BREAKER DISTRIBUTION, 800A, INCLUDING: - QTY 24 ONE POLE BULLET BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS. EACH LANDING REQUIRES A TWO-HOLE LUG WITH 1/4 HOLE ON 5/8 CENTER, MAX CABLE TONGUE WIDTH OF 5/8 PER CONNECTION NO INTERNAL RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER Learn More -
150A 2P BREAKER KIT TWO POLE CIRCUI
150A 2P BREAKER KIT TWO POLE CIRCUIT BREAKER THAT TAKES UP TWO CIRCUIT BREAKER POSITIONS IN THE DISTRIBUTION. INCLUDES: BUS PAD KIT FOR 2P BREAKERS 3/8 HOLE ON 1 CENTERS Learn More -
CIRCUIT BREAKER, 30 AMP PLUG-IN BUL
CIRCUIT BREAKER, 30 AMP PLUG-IN BULLET, ELECTRO-MECHANICAL Learn More -
AC LINE CORD, 10', 8AWG, 1 HOLE LUG
AC LINE CORD, 10', 8AWG, 1 HOLE LUG TO UN-TERMINATED Learn More -
SPS BUS LINK GEN3 10KA Qty 2 (One p
SPS BUS LINK GEN3 10KA Qty 2 (One per polarity), 10kA Bus Links with hardware Connects any GEN3 Bay to any another GEN3 Bay Learn More -
FP2 SYSTEM / REAR WIRE 168AMP MAX
FP2 SYSTEM / REAR WIRE 168AMP MAX ****RACK MOUNTED**** 48V NEGATIVE POLARITY OUTPUT VOLTAGE 19 / RACK MOUNTED / NON-SEISMIC INDIVIDUAL AC INPUT (LU AC CORD) QTY 4 RECTIFIER POSITIONS QTY 4 DISTRIBUTION CIRCUIT BREAKER POSITIONS UP TO 100AMP (CBE STYLE) 1/4-20 STUD 5/8 CENTER QTY 2 LVBD CIRCUIT BREAKER POSITIONS (CBE STYLE) 1/4-20 STUD 5/8 CENTER QTY.1 BATTERY TRAY W/100A CIRCUIT BREAKER DISCONNECT MOUNTED IN SYSTEM & CABLE 7' NON-SEISMIC 19 RELAY RACK DISTRIBUTION HAS THE CAPABILITY TO USE A TWO POLE BREAKER IN PLACE OF TWO SINGLE POLE BREAKERS. SMARTPACK WEB .118 INCLUDED CONTROLLER CARD INCLUDED Learn More -
PLUG NEMA NON-LOCKING N5-30P
PLUG NEMA NON-LOCKING N5-30P Learn More -
SPS RECTIFIER BAY, 208VAC, INDIVID
SPS RECTIFIER BAY, 208VAC, INDIVIDUAL FEED, TERMINAL BLOCKS, 3450A OUTPUT POWERPACK RECTIFIER BAY, QTY 15 RECTIFIER POSITIONS, 3 PHASE 208VAC AC FEED, ONE RECTIFIER PER AC FEED, TOTAL 15 AC FEEDS, EVERY AC FEED INCLUDES 3 TERMINAL BLOCKS, EVERY TERMINAL BLOCK ACCEPTS MAX. 4 AWG CABLE 6KA REAR BUS STRUCTURE INCLUDES: 6KA HOT AND RETURN BUSES, QTY 8 CONNECTION LANDINGS, EACH LANDING INCLUDES TWO 3/8-16x1.25 STUDS ON 1 CENTER NO CONTROLLER FOR EXPANSION RECTIFIER BAY, COMPATIBLE WITH SMARTPACK2 CONTROLLER Learn More -
FP2 SYSTEM / REAR WIRE 168AMP MAX
FP2 SYSTEM / REAR WIRE 168AMP MAX 48V NEGATIVE POLARITY OUTPUT VOLTAGE 19 / 2RU / MID MOUNT DUAL AC INPUT (LU AC CORD) QTY 4 RECTIFIER POSITIONS QTY 6 DISTRIBUTION CIRCUIT BREAKER POSITIONS UP TO 100AMP (CBE STYLE) 1/4-20 STUD 5/8 CENTER QTY 2 BATTERY LVD/SHUNT BULK LANDINGS 1/4-20 STUD 5/8 CENTER DISTRIBUTION HAS THE CAPABILITY TO USE A TWO POLE BREAKER IN PLACE OF TWO SINGLE POLE BREAKERS. SMARTPACK WEB .118 CONTROLLER CARD INCLUDED Learn More -
BATTERY THERMAL PROBE KIT - PADDLE,
BATTERY THERMAL PROBE KIT - PADDLE, 20 FT. Learn More -
SPS RECTIFIER BAY, 480VAC, TWO REC
SPS RECTIFIER BAY, 480VAC, TWO RECTIFIERS PER FEED, TERMINAL BLOCKS, 3450A OUTPUT POWERPACK RECTIFIER BAY, QTY 15 RECTIFIER POSITIONS, 3 PHASE 480VAC AC FEED, TWO RECTIFIERS PER AC FEED, TOTAL 8 AC FEEDS, EVERY AC FEED INCLUDES 3 TERMINAL BLOCKS, EVERY TERMINAL BLOCK ACCEPTS MAX. 1/0 AWG CABLE RAISED 3KA BUS STRUCTURE INCLUDES: 3KA HOT AND RETURN BUSES, QTY 10 (20 BACK TO BACK) CONNECTION LANDINGS ON BOTH BUSES, EACH LANDING INCLUDES TWO 3/8 HOLES ON 1 CENTER NO CONTROLLER FOR EXPANSION RECTIFIER BAY, COMPATIBLE WITH SMARTPACK2 CONTROLLER Learn More -
INTEGRATED SYSTEM / REAR WIRE 300
INTEGRATED SYSTEM / REAR WIRE 300AMP MAX 24V NEGATIVE POLARITY OUTPUT VOLTAGE 23 / 10RU / MID MOUNT INDIVIDUAL AC INPUT PER RECTIFIER (LL AC CORD) QTY 5 RECTIFIER POSITIONS QTY 48 DISTRIBUTION CIRCUIT BREAKER POSITIONS (CBB STYLE) 1/4-20 STUD 5/8 CENTER REAR BATTERY SHUNT BUS BAR 4QTY POSITIONS 1/4-20 STUD 5/8 CENTER OR 4QTY 3/8 - 1 CENTER BC CONTROLLER CARD NOT INCLUDED Q2430N-23ID07-C13-C Learn More -
19 TO 23 2RU ADAPTOR BRACKET KIT
19 TO 23 2RU ADAPTOR BRACKET KIT Learn More