ECOTOWER 480VAC POWERPACK RECTIFIER

Availability: In stock

$0.00

Quick Overview

ECOTOWER 480VAC POWERPACK RECTIFIER BASE, -48V/2292A OUTPUT
INCLUDES: CABINET, QTY 10 POWERPACK RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT.
- CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET
- EACH RECTIFIER SHELF HAS 1 RECTIFIER POSITIONS, TOTAL 10 RECTIFIER POSITIONS
- SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS)

THREE PHASE 480VAC (3W+PE) INPUT, 1 RECTIFIER PER AC INPUT FEED, REAR ACCESS
INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX.
- AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE.
- CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY
- AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS

BATTERY BULK OUTPUT PANEL, 2000A WITH LVBD AND SHUNT PANEL IS EQUIPPED WITH: LOW VOLTAGE BATTERY DISCONNECT AND 50mV/3000A SHUNT
QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION

LOAD FUSE DISTRIBUTION, 1200A, INCLUDING:
- QTY 18 TPL FUSE POSITIONS OR 36 GJ BREAKER POSITIONS WITH 36 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION. LOAD FUSE DISTRIBUTION, 1200A, INCLUDING:

QTY - 2 GJ500M BREAKERS INCLUDED
QTY - 6 GJ250M BREAKERS INCLUDED
QTY - 12 GJ200M BREAKERS INCLUDED
QTY - 12 GJ125M BREAKERS INCLUDED

- BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER
- RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS.
EPS-S13-A10-B04-D05-D05-D05-G W/BRK

Details

ECOTOWER 480VAC POWERPACK RECTIFIER BASE, -48V/2292A OUTPUT INCLUDES: CABINET, QTY 10 POWERPACK RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24" WIDE, 24" DEEP, 7' HIGH (84"" HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 1 RECTIFIER POSITIONS, TOTAL 10 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) THREE PHASE 480VAC (3W+PE) INPUT, 1 RECTIFIER PER AC INPUT FEED, REAR ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5"" CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4""-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2000A WITH LVBD AND SHUNT PANEL IS EQUIPPED WITH: LOW VOLTAGE BATTERY DISCONNECT AND 50mV/3000A SHUNT QTY 8 - 3/8"" ON 1"" CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25"" PER CONNECTION LOAD FUSE DISTRIBUTION, 1200A, INCLUDING: - QTY 18 TPL FUSE POSITIONS OR 36 GJ BREAKER POSITIONS WITH 36 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8"" HOLE ON 1"" CENTER, MAX CABLE TONGUE WIDTH OF 1.5"" PER CONNECTION. LOAD FUSE DISTRIBUTION, 1200A, INCLUDING: QTY - 2 GJ500M BREAKERS INCLUDED QTY - 6 GJ250M BREAKERS INCLUDED QTY - 12 GJ200M BREAKERS INCLUDED QTY - 12 GJ125M BREAKERS INCLUDED - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8""-16 NUTS ON 1"" CENTER - RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS. EPS-S13-A10-B04-D05-D05-D05-G W/BRK

Additional Info

Short Description ECOTOWER 480VAC POWERPACK RECTIFIER BASE, -48V/2292A OUTPUT INCLUDES: CABINET, QTY 10 POWERPACK RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 1 RECTIFIER POSITIONS, TOTAL 10 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) THREE PHASE 480VAC (3W+PE) INPUT, 1 RECTIFIER PER AC INPUT FEED, REAR ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2000A WITH LVBD AND SHUNT PANEL IS EQUIPPED WITH: LOW VOLTAGE BATTERY DISCONNECT AND 50mV/3000A SHUNT QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION LOAD FUSE DISTRIBUTION, 1200A, INCLUDING: - QTY 18 TPL FUSE POSITIONS OR 36 GJ BREAKER POSITIONS WITH 36 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION. LOAD FUSE DISTRIBUTION, 1200A, INCLUDING: QTY - 2 GJ500M BREAKERS INCLUDED QTY - 6 GJ250M BREAKERS INCLUDED QTY - 12 GJ200M BREAKERS INCLUDED QTY - 12 GJ125M BREAKERS INCLUDED - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER - RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS. EPS-S13-A10-B04-D05-D05-D05-G W/BRK