ECOTOWER 480VAC POWERPACK RECTIFIER

Availability: In stock

$0.00

Quick Overview

ECOTOWER 480VAC POWERPACK RECTIFIER BASE, -48V/2292A OUTPUT

INCLUDES: CABINET, QTY 10 POWERPACK RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT.

- CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET
- EACH RECTIFIER SHELF HAS 1 RECTIFIER POSITIONS, TOTAL 10 RECTIFIER POSITIONS

- SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS)

THREE PHASE 480VAC (3W+PE) INPUT, 1 RECTIFIER PER AC INPUT FEED, FRONT ACCESS

INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX.

- AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE.

- CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY

- AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS

BATTERY BULK OUTPUT PANEL, 2400A WITH SHUNT

PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD

QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION

LOAD FUSE DISTRIBUTION WITH LOAD SHUNT MONITOR, 2400A. INCLUDING:

- QTY 12 TPL FUSE POSITIONS OR 12 GS BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION.

- QTY 2 LOAD MONITOR KIT, MONITORS QTY 12 LOAD SHUNTS

INTERNAL RETURN BUS BAR INCLUDES:

- BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER
RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS.
EPS-S13-A05-B03-D07S-D07S-G

Details

ECOTOWER 480VAC POWERPACK RECTIFIER BASE, -48V/2292A OUTPUT INCLUDES: CABINET, QTY 10 POWERPACK RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24" WIDE, 24" DEEP, 7' HIGH (84" HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 1 RECTIFIER POSITIONS, TOTAL 10 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) THREE PHASE 480VAC (3W+PE) INPUT, 1 RECTIFIER PER AC INPUT FEED, FRONT ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5" CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4"-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2400A WITH SHUNT PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD QTY 8 - 3/8" ON 1" CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25" PER CONNECTION LOAD FUSE DISTRIBUTION WITH LOAD SHUNT MONITOR, 2400A. INCLUDING: - QTY 12 TPL FUSE POSITIONS OR 12 GS BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8" HOLE ON 1" CENTER, MAX CABLE TONGUE WIDTH OF 1.5" PER CONNECTION. - QTY 2 LOAD MONITOR KIT, MONITORS QTY 12 LOAD SHUNTS INTERNAL RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8"-16 NUTS ON 1" CENTER RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS. EPS-S13-A05-B03-D07S-D07S-G

Additional Info

Short Description ECOTOWER 480VAC POWERPACK RECTIFIER BASE, -48V/2292A OUTPUT INCLUDES: CABINET, QTY 10 POWERPACK RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 1 RECTIFIER POSITIONS, TOTAL 10 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) THREE PHASE 480VAC (3W+PE) INPUT, 1 RECTIFIER PER AC INPUT FEED, FRONT ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2400A WITH SHUNT PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION LOAD FUSE DISTRIBUTION WITH LOAD SHUNT MONITOR, 2400A. INCLUDING: - QTY 12 TPL FUSE POSITIONS OR 12 GS BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION. - QTY 2 LOAD MONITOR KIT, MONITORS QTY 12 LOAD SHUNTS INTERNAL RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS. EPS-S13-A05-B03-D07S-D07S-G
SKU 306178
Product PDF N/A
HECI No
Manufacturer Eltek
Product Type N/A
Special Price No