EPS-S02-A06-B03-D07S-D07S-D07S-G EC

Availability: In stock

$0.00

Quick Overview

EPS-S02-A06-B03-D07S-D07S-D07S-G
ECOTOWER FP2 3KW RECTIFIER BASE, -48V/2400A OUTPUT
INCLUDES: CABINET, QTY 10 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT.
- CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET
- EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 40 RECTIFIER POSITIONS
- SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS)

SINGLE PHASE 208V/240V AC INPUT, 2 RECTIFIERS PER AC INPUT FEED, REAR ACCESS
INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX.
- AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF TWO TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE.
- CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY
- AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS

BATTERY BULK OUTPUT PANEL, 2400A
PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD
QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION
RETURN BUS PANEL FOR BATTERY RETURN CONNECTION

QTY 3 LOAD FUSE DISTRIBUTION WITH LOAD SHUNT MONITOR, 2400A. EACH DISTRIBUTION INCLUDING:
- QTY 6 TPL FUSE POSITIONS OR 12 GS BREAKER POSITIONS WITH 12 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION.
- QTY 1 LOAD MONITOR KIT, MONITORS QTY 6 LOAD SHUNTS

INTERNAL RETURN BUS BAR INCLUDES:
- BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER
- RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS.

Details

EPS-S02-A06-B03-D07S-D07S-D07S-G ECOTOWER FP2 3KW RECTIFIER BASE, -48V/2400A OUTPUT INCLUDES: CABINET, QTY 10 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24"" WIDE, 24"" DEEP, 7' HIGH (84"" HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 40 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) SINGLE PHASE 208V/240V AC INPUT, 2 RECTIFIERS PER AC INPUT FEED, REAR ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF TWO TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5"" CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4""-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2400A PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD QTY 8 - 3/8"" ON 1"" CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25"" PER CONNECTION RETURN BUS PANEL"" FOR BATTERY RETURN CONNECTION QTY 3 LOAD FUSE DISTRIBUTION WITH LOAD SHUNT MONITOR, 2400A. EACH DISTRIBUTION INCLUDING: - QTY 6 TPL FUSE POSITIONS OR 12 GS BREAKER POSITIONS WITH 12 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8" HOLE ON 1" CENTER, MAX CABLE TONGUE WIDTH OF 1.5" PER CONNECTION. - QTY 1 LOAD MONITOR KIT, MONITORS QTY 6 LOAD SHUNTS INTERNAL RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8"-16 NUTS ON 1" CENTER - RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS.

Additional Info

Short Description EPS-S02-A06-B03-D07S-D07S-D07S-G ECOTOWER FP2 3KW RECTIFIER BASE, -48V/2400A OUTPUT INCLUDES: CABINET, QTY 10 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 40 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) SINGLE PHASE 208V/240V AC INPUT, 2 RECTIFIERS PER AC INPUT FEED, REAR ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF TWO TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2400A PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION RETURN BUS PANEL FOR BATTERY RETURN CONNECTION QTY 3 LOAD FUSE DISTRIBUTION WITH LOAD SHUNT MONITOR, 2400A. EACH DISTRIBUTION INCLUDING: - QTY 6 TPL FUSE POSITIONS OR 12 GS BREAKER POSITIONS WITH 12 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION. - QTY 1 LOAD MONITOR KIT, MONITORS QTY 6 LOAD SHUNTS INTERNAL RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER - RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS.
SKU 320738
Product PDF N/A
HECI No
Manufacturer Eltek
Product Type N/A