EPS-S01-A01-B21-D5-D11-G ECOTOWER F

Availability: In stock

$0.00

Quick Overview

EPS-S01-A01-B21-D5-D11-G
ECOTOWER FP2 3KW RECTIFIER BASE, -48V/1200A OUTPUT
INCLUDES: CABINET, QTY 5 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT.
- CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET
- EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 20 RECTIFIER POSITIONS
- SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS)

SINGLE PHASE 208V/240V AC INPUT, 2 RECTIFIERS PER AC INPUT FEED, FRONT ACCESS
INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX.
- AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF TWO TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE.
- CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY
- AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS

BATTERY FUSE OUTPUT PANEL, 1200A WITH SHUNT AND LVBD
PANEL IS EQUIPPED WITH:
- QTY 6 TPL (OR 12 GJ BREAKER) POSITIONS, LOW VOLTAGE BATTERY DISCONNECT AND 50mV/2000A SHUNT
- QTY 12 - 3/8 ON 1 CENTER BATTERY HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION
SEE SECTION 5 RETURN BUS PANEL FOR BATTERY RETURN CONNECTION

QTY 1 LOAD FUSE DISTRIBUTIONS, 1200A PER DISTRIBUTION, EACH DISTRIBUITON INCLUDES:
- QTY 6 TPL POSITIONS OR 12 GS BREAKER POSITIONS WITH 12 LOAD LANDINGS, EACH LANDING REQUIRES A TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION

QTY 1 LOAD BREAKER DISTRIBUTION, 800A PER DISTRIBUTION, EACH DISTRIBUTION INCLUDING
- QTY 24 ONE POLE BULLET BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS. EACH LANDING REQUIRES A TWO-HOLE LUG WITH 1/4 HOLE ON 5/8 CENTER, MAX CABLE TONGUE WIDTH OF 5/8 PER CONNECTION

INTERNAL RETURN BUS BAR INCLUDES:
- BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER
- QTY 2 RETURN BUS RIBS FOR BATTER/LOAD FUSE AND LOAD BREAKER RETURN.

Details

EPS-S01-A01-B21-D5-D11-G ECOTOWER FP2 3KW RECTIFIER BASE, -48V/1200A OUTPUT INCLUDES: CABINET, QTY 5 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24" WIDE, 24" DEEP, 7' HIGH (84" HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 20 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) SINGLE PHASE 208V/240V AC INPUT, 2 RECTIFIERS PER AC INPUT FEED, FRONT ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF TWO TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5" CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4"-20) AND MOUNTING BRACKETS BATTERY FUSE OUTPUT PANEL, 1200A WITH SHUNT AND LVBD PANEL IS EQUIPPED WITH: - QTY 6 TPL (OR 12 GJ BREAKER) POSITIONS, LOW VOLTAGE BATTERY DISCONNECT AND 50mV/2000A SHUNT - QTY 12 - 3/8" ON 1" CENTER BATTERY HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 1.5" PER CONNECTION SEE SECTION 5 "RETURN BUS PANEL" FOR BATTERY RETURN CONNECTION QTY 1 LOAD FUSE DISTRIBUTIONS, 1200A PER DISTRIBUTION, EACH DISTRIBUITON INCLUDES: - QTY 6 TPL POSITIONS OR 12 GS BREAKER POSITIONS WITH 12 LOAD LANDINGS, EACH LANDING REQUIRES A TWO-HOLE LUG WITH 3/8" HOLE ON 1" CENTER, MAX CABLE TONGUE WIDTH OF 1.5" PER CONNECTION QTY 1 LOAD BREAKER DISTRIBUTION, 800A PER DISTRIBUTION, EACH DISTRIBUTION INCLUDING - QTY 24 ONE POLE BULLET BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS. EACH LANDING REQUIRES A TWO-HOLE LUG WITH 1/4" HOLE ON 5/8" CENTER, MAX CABLE TONGUE WIDTH OF 5/8" PER CONNECTION INTERNAL RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8"-16 NUTS ON 1" CENTER - QTY 2 RETURN BUS RIBS FOR BATTER/LOAD FUSE AND LOAD BREAKER RETURN.

Additional Info

Short Description EPS-S01-A01-B21-D5-D11-G ECOTOWER FP2 3KW RECTIFIER BASE, -48V/1200A OUTPUT INCLUDES: CABINET, QTY 5 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 20 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) SINGLE PHASE 208V/240V AC INPUT, 2 RECTIFIERS PER AC INPUT FEED, FRONT ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF TWO TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS BATTERY FUSE OUTPUT PANEL, 1200A WITH SHUNT AND LVBD PANEL IS EQUIPPED WITH: - QTY 6 TPL (OR 12 GJ BREAKER) POSITIONS, LOW VOLTAGE BATTERY DISCONNECT AND 50mV/2000A SHUNT - QTY 12 - 3/8 ON 1 CENTER BATTERY HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION SEE SECTION 5 RETURN BUS PANEL FOR BATTERY RETURN CONNECTION QTY 1 LOAD FUSE DISTRIBUTIONS, 1200A PER DISTRIBUTION, EACH DISTRIBUITON INCLUDES: - QTY 6 TPL POSITIONS OR 12 GS BREAKER POSITIONS WITH 12 LOAD LANDINGS, EACH LANDING REQUIRES A TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION QTY 1 LOAD BREAKER DISTRIBUTION, 800A PER DISTRIBUTION, EACH DISTRIBUTION INCLUDING - QTY 24 ONE POLE BULLET BREAKER POSITIONS WITH 24 LOAD HOT LANDINGS. EACH LANDING REQUIRES A TWO-HOLE LUG WITH 1/4 HOLE ON 5/8 CENTER, MAX CABLE TONGUE WIDTH OF 5/8 PER CONNECTION INTERNAL RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER - QTY 2 RETURN BUS RIBS FOR BATTER/LOAD FUSE AND LOAD BREAKER RETURN.