Shop Now
-
COMPACT POWER SHELF / FRONT WIRE 1
COMPACT POWER SHELF / FRONT WIRE 150AMP MAX 48V NEGATIVE OUTPUT POLARITY 19 / 2 RU / MID MOUNT / SYSTEM DEPTH 12 DUAL AC INPUT (LM AC CORD) QTY 3 RECTIFIER POSITIONS QTY 2 LOAD BREAKER POSITIONS #10-32 STUDS 5/8 CENTERS QTY 2 LOAD BULK POSITIONS 1/4-20 STUDS 5/8 CENTERS (TOP ACCESS) QTY 2 SHUNT BREAKER POSITIONS #10-32 STUD 5/8 CENTER QTY 10 GMT FUSE POSITIONS BC CONTROLLER CARD NOT INCLUDED DERATES TO 120A ABOVE +40?C Learn More -
INTEGRATED SYSTEM / REAR WIRE 250
INTEGRATED SYSTEM / REAR WIRE 250AMP MAX 48V NEGATIVE POLARITY OUTPUT VOLTAGE 23 / 6RU / MID MOUNT DUAL AC INPUT PER RECTIFIER SHELF (LL AC CORD) QTY 5 RECTIFIER POSITIONS QTY 20 DISTRIBUTION CIRCUIT BREAKER POSITIONS (CBB STYLE) 1/4-20 STUD 5/8 CENTER QTY 4 LVBD CIRCUIT BREAKER POSITIONS (CBB STYLE) 1/4-20 STUD 5/8 CENTER QTY 4 BATTERY TRAYS NO BREAKER QTY 4 #4AWG BATTERY CABLES 7' NON-SEISMIC 23 BOLTED RELAY RACK BC CONTROLLER CARD NOT INCLUDED Learn More -
CIRCUIT BREAKER, 60 AMP BULLET BRE
CIRCUIT BREAKER, 60 AMP BULLET BREAKER Learn More -
RECTIFIER, 1400W, 53.5V, 25A, FAN C
RECTIFIER, 1400W, 53.5V, 25A, FAN C Learn More -
EPS-S02-A06-B03-D07S-D07S-D07S-G EC
EPS-S02-A06-B03-D07S-D07S-D07S-G ECOTOWER FP2 3KW RECTIFIER BASE, -48V/2400A OUTPUT INCLUDES: CABINET, QTY 10 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 40 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) SINGLE PHASE 208V/240V AC INPUT, 2 RECTIFIERS PER AC INPUT FEED, REAR ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF TWO TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2400A PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION RETURN BUS PANEL FOR BATTERY RETURN CONNECTION QTY 3 LOAD FUSE DISTRIBUTION WITH LOAD SHUNT MONITOR, 2400A. EACH DISTRIBUTION INCLUDING: - QTY 6 TPL FUSE POSITIONS OR 12 GS BREAKER POSITIONS WITH 12 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION. - QTY 1 LOAD MONITOR KIT, MONITORS QTY 6 LOAD SHUNTS INTERNAL RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER - RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS. Learn More -
175A 2P BREAKER KIT TWO POLE CIRCUI
175A 2P BREAKER KIT TWO POLE CIRCUIT BREAKER THAT TAKES UP TWO CIRCUIT BREAKER POSITIONS IN THE DISTRIBUTION. INCLUDES: BUS PAD KIT FOR 2P BREAKERS 3/8 HOLE ON 1 CENTERS Learn More -
CIRCUIT BREAKER, 35 AMP PLUG-IN BUL
CIRCUIT BREAKER, 35 AMP PLUG-IN BULLET, ELECTRO-MECHANICAL Learn More -
AC LINE CORD, 10', 10AWG, 1 HOLE LU
AC LINE CORD, 10', 10AWG, 1 HOLE LUG TO L530P Learn More -
SPS UPGRADE REC BAY REAR BUS TO 6KA
SPS UPGRADE REC BAY REAR BUS TO 6KA Qty 2 (One per polarity), 6kA Rectifier Bay Bus Bar Upgrade Kit Increases 3,000 Amp Rear Lateral Bus capacity to 6,000 Amps Learn More -
FP2 SYSTEM / REAR WIRE 168AMP MAX
FP2 SYSTEM / REAR WIRE 168AMP MAX 48V NEGATIVE POLARITY OUTPUT VOLTAGE 19 / 2RU / MID MOUNT DUAL AC INPUT (LU AC CORD) QTY 4 RECTIFIER POSITIONS QTY 2 DISTRIBUTION CIRCUIT BREAKER POSITIONS (CBE STYLE) 1/4-20 STUD 5/8 CENTER QTY 2 BATTERY SHUNT CIRCUIT BREAKER POSITIONS (CBE STYLE) 1/4-20 STUD 5/8 CENTER DISTRIBUTION HAS THE CAPABILITY TO USE A TWO POLE BREAKER IN PLACE OF TWO SINGLE POLE BREAKERS. SMARTPACK WEB .118 CONTROLLER CARD INCLUDED INCLUDES QTY 2 175AMP BATTERY/LOAD CIRCUIT BREAKERS Learn More -
PLUG NEMA LOCKING L14-30P
PLUG NEMA LOCKING L14-30P Learn More -
SPS RECTIFIER BAY, 208VAC, TWO REC
SPS RECTIFIER BAY, 208VAC, TWO RECTIFIERS PER FEED, TERMINAL BLOCKS, 3450A OUTPUT POWERPACK RECTIFIER BAY, QTY 15 RECTIFIER POSITIONS, 3 PHASE 208VAC AC FEED TWO RECTIFIERS PER AC FEED, TOTAL 8 AC FEEDS, EVERY AC FEED INCLUDES 3 TERMINAL BLOCKS, EVERY TERMINAL BLOCK ACCEPTS MAX. 1/0 AWG CABLE RAISED 3KA BUS STRUCTURE INCLUDES: 3KA HOT AND RETURN BUSES, QTY 10 (20 BACK TO BACK) CONNECTION LANDINGS ON BOTH BUSES, EACH LANDING INCLUDES TWO 3/8 HOLES ON 1 CENTER SMARTPACK2 CONTROLLER, INCLUDING SMARTPACK2 BASIC (242100.501) WITH SD CARD, SMARTPACK2 MASTER (242100.500), AND QTY 2 I/O MONITOR MODULES (242100.502). QTY 12 FORM-C RELAY OUTPUTS, QTY 12 CONFIGURABLE INPUTS, ETHERNET PORT FOR REMOTE OR LOCAL MONITORING AND CONTROL. Learn More -
FP2 SYSTEM / REAR WIRE 600 AMP MA
FP2 SYSTEM / REAR WIRE 600 AMP MAX ****RACK MOUNTED**** 48V NEGATIVE POLARITY OUTPUT VOLTAGE 23 / 7' RACK SEISMIC DUAL AC INPUT PER RECTIFIER SHELF (LU AC CORD) QTY 16 RECTIFIER POSITIONS TOP QTY 24 POSITION SHARED 3 BAR DISTRIBUTION PANEL (CBE STYLE) 1/4-20 STUD 5/8 CENTER TOP BUS BAR IS UNUSED MIDDLE BUS BAR IS UNUSED BOTTOM BUS BAR IS LOAD DISTRIBUTION BOTTOM QTY 24 POSITION SHARED 3 BAR DISTRIBUTION PANEL (CBE STYLE) 1/4-20 STUD 5/8 CENTER TOP BUS BAR IS UNUSED MIDDLE BUS BAR IS UNUSED BOTTOM BUS BAR IS LOAD DISTRIBUTION REAR BATTERY SHUNT BUS BAR POSITIONS 8QTY 3/8 - 1 CENTER SMARTPACK EXTENDED QTY 3 BATTERY TRAYS QTY 3 200 AMP BATTERY DISCONNECT CIRCUIT BREAKERS DC BATTERY CABLE (TO EACH DISCONNECT BREAKER) SMARTPACK .118 WEB CONTROLLER CARD INCLUDED Learn More -
GMT FUSE 15.0
GMT FUSE 15.0 Learn More -
SPS RECTIFIER BAY, 480VAC, TWO REC
SPS RECTIFIER BAY, 480VAC, TWO RECTIFIERS PER FEED, TERMINAL BLOCKS, 3450A OUTPUT POWERPACK RECTIFIER BAY, QTY 15 RECTIFIER POSITIONS, 3 PHASE 480VAC AC FEED, TWO RECTIFIERS PER AC FEED, TOTAL 8 AC FEEDS, EVERY AC FEED INCLUDES 3 TERMINAL BLOCKS, EVERY TERMINAL BLOCK ACCEPTS MAX. 1/0 AWG CABLE 3KA REAR BUS STRUCTURE INCLUDES: 3KA HOT AND RETURN BUSES, QTY 8 CONNECTION LANDINGS ON BOTH BUSES, EACH LANDING INCLUDES TWO 3/8-16x1.25 STUDS ON 1 CENTER NO CONTROLLER FOR EXPANSION RECTIFIER BAY, COMPATIBLE WITH SMARTPACK2 CONTROLLER Learn More